Hurstbridge Football & Cricket Pavilion
Reading time: 7min

Commercial Solar and Scope 2 Emissions: What Your Business Can Measure and Report

Solar Series · Part 2 of 5 Group 2 Carbon Reporting
  1. 1 Group 2 Climate Reporting: What Businesses Need to Do in 2026 and 2027
  2. 2 Commercial Solar and Scope 2 Emissions: What Your Business Can Measure and Report
  3. 3 Carbon Reporting for Small Businesses and Suppliers: What to Do When a Customer Asks for Emissions Data
  4. 4 Commercial Battery Storage and Carbon Emissions: What Your Business Can Measure and Report
  5. 5 Carbon Reporting for Small Businesses: Why Customers May Request Emissions Data
View full series →

Commercial solar can reduce the electricity your business buys from the grid and support lower Scope 2 emissions. The reportable result depends on how much solar electricity your site uses, the accounting method and who holds the associated renewable energy claims.

For finance and operations teams, the starting point is a clear record of electricity generated, consumed, imported and exported. Those figures help assess the investment and give your reporting advisers the evidence needed to calculate emissions.

How solar affects purchased electricity emissions

Scope 2 emissions arise from electricity, steam, heating and cooling purchased or acquired by an organisation. At many commercial and industrial sites, grid electricity is a major part of this category.

When your facility uses solar electricity as it is generated, it needs less grid electricity to meet the same demand. That physical reduction is measurable. Whether it produces a corresponding reduction in reported emissions requires a separate accounting check.

A worked example of solar generation and grid savings

Consider a facility that uses 1,000,000 kWh of electricity annually. It installs solar, has no battery and maintains the same total electricity consumption. The following figures are illustrative.

Annual electricity measure Before solar After solar
Total site consumption 1,000,000 kWh 1,000,000 kWh
Solar generation 0 kWh 400,000 kWh
Solar used on site 0 kWh 320,000 kWh
Solar exported to the grid 0 kWh 80,000 kWh
Electricity imported from the grid 1,000,000 kWh 680,000 kWh

Grid purchases fall by 320,000 kWh, or 32%. The exported 80,000 kWh does not replace electricity consumed at this facility.

Two percentages describe different outcomes:

  • Solar self-consumption is 80%. The facility uses 320,000 kWh of the 400,000 kWh generated.
  • Solar supplies 32% of site electricity. The facility uses 320,000 kWh of solar within its total consumption of 1,000,000 kWh.

Neither figure means the facility is 80% renewable or that its electricity bill falls by 32%. Bill savings also depend on tariffs, demand charges, fixed charges and export credits.

Two Scope 2 reporting methods

Location-based reporting uses average emissions factors for the electricity grid serving a site. Market-based reporting reflects qualifying electricity contracts and energy attribute claims, with an appropriate factor for consumption those arrangements do not cover.

Under AASB S2, businesses must disclose location-based Scope 2 emissions and relevant information about contractual instruments. A market-based figure can be disclosed additionally; it does not replace the required location-based figure.

For the example above, a simplified location-based comparison would apply the relevant grid factor to 1,000,000 kWh before solar and 680,000 kWh afterwards. This assumes the business owns and operates the solar system, retains the necessary energy attributes and uses a method that permits this treatment.

With the same factor in both calculations, purchased-electricity emissions would fall by 32%. Actual annual results may differ because factors, operations or certificate arrangements change. Your adviser should document the factor, reporting period, boundary and treatment of solar.

Check certificates before making an emissions claim

Using solar electricity and holding the right to claim its renewable attributes are separate matters. Where energy attribute certificates are sold to another party, the site consuming the electricity cannot automatically claim the associated zero-emissions benefit.

GHG Protocol guidance explains that selling those attributes can affect both location-based and market-based accounting for directly consumed generation. It is not only a market-based reporting issue.

Australian projects may involve large-scale generation certificates (LGCs) or small-scale technology certificates (STCs). These are different schemes. STCs can support an upfront installation discount; do not automatically apply the accounting treatment for selling LGCs to an STC-supported system.

Before approving a solar contract or publishing a claim, confirm with your reporting adviser:

  • Which certificates or environmental attributes arise under the project.
  • Who owns them, and whether they are sold, assigned, retained or surrendered.
  • What claim the relevant reporting framework permits, supported by those records.

Record exports separately from imports

Solar exports are not an automatic deduction from Scope 2 emissions. In the example, the business still imports 680,000 kWh. Subtracting its 80,000 kWh of exports again would understate those imports.

An eligible certificate-backed arrangement might support a separate market-based claim. That is different from netting meter readings. Any estimate of emissions avoided elsewhere in the electricity system should be reported separately from the business’s Scope 2 inventory, with its own method and assumptions.

Keep the records needed to explain the result

Set up monitoring and data access before installation. Electricity bills alone usually do not show how much solar the facility used behind the meter.

Record What it establishes
Site and meter details Which facility, account and reporting period the data covers.
Grid import and export data Electricity bought from and supplied to the grid, recorded separately.
Solar generation and monitoring data Actual output and the information needed to calculate on-site use.
Contracts and certificate records System ownership, electricity purchasing terms and rights to environmental claims.
Baseline and calculation records The comparison period, factors, estimates and operational changes behind the result.

Keep downloadable records, not just access to a live dashboard. Assign responsibility for checking missing readings, reconciling data and retaining the calculation. If a battery is present, account for charging, discharge and losses rather than relying on a simple generation-minus-exports calculation.

Compare performance against a defined baseline

Select a representative period before installation and record operating hours, production, occupancy and existing generation. Compare it with the same seasonal period after commissioning.

A factory adding a production line could use more electricity overall while importing less because solar supplies part of the new load. A warehouse reducing its operating hours could show lower imports for reasons unrelated to solar. Explain these changes before attributing the entire difference to the project.

Keep modelled savings separate from measured performance. Report actual generation and consumption for the period available. Do not present a few months of operation extrapolated to a full year as a measured annual result.

Assess the system against your operating pattern

A suitable commercial solar system starts with when the business uses electricity. Annual bills cannot show whether generation will match demand during working hours, weekends or seasonal shutdowns.

For example, a manufacturer running weekday shifts and a refrigerated facility operating continuously may use the same annual electricity but need different designs. Interval meter data helps assess how much proposed generation each site could use.

The assessment should also consider roof condition, structural suitability, switchboard capacity, network and export limits, tenancy arrangements and planned changes such as EV charging or electrification.

Compare expected self-consumption, exports, financial savings and the information needed for emissions reporting. A larger system can increase exports without producing an equivalent increase in grid savings at the site.

Common questions about solar and emissions reporting

What if the solar system is supplied under a PPA

Electricity bought under an on-site power purchase agreement is still purchased electricity. Panels being on your roof do not, by themselves, place that electricity outside Scope 2. Check the reporting boundary, contract and environmental attributes before assigning an emissions factor.

Does installing solar make the business carbon neutral

No. A solar project does not establish a carbon-neutral result for the organisation. Other electricity purchases, fuels and value-chain emissions remain relevant. Describe the measured project outcome rather than making a broader claim the evidence does not support.

Request a commercial solar assessment

Melbourne Energy Group can assess your site’s electricity use, solar feasibility and system design, and discuss monitoring requirements. This gives your finance and operations teams a basis for evaluating the project and identifying the data your reporting advisers will need.

To start, share recent electricity bills, your site location, operating hours and details of any existing solar system. Include interval meter data if available. If you have a reporting requirement or emissions target, raise it early so the project and data requirements can be considered together.

Request a Commercial Solar Assessment

MEG provides energy project and performance information. Your reporting advisers remain responsible for carbon accounting, statutory disclosures and assurance.

Shane_Smillie
Shane Smillie
Managing Director

Innovator and leader with over 15 years of extensive experience within the electrical industry. Knowledge in all aspects of business formation, development, operation, management and finance. An effective communicator and motivator with excellent time management skills, optimist attitude and calm nature. More articles by Shane Smillie